Cqr Fp2 Installation Manual

  • Published on
    10-Sep-2015

  • View
    44

  • Download
    5

DESCRIPTION

Eltek

Transcript

  • www.eltekenergy.com I www.flatpack2.com

    Flatpack2 48/2000 Switch Mode Power Supply 48VDC

    Key Features

    Highest efficiency in minimum space Resonant topology makes the module efficiency industry

    leading and contributes to the rectifiers ultra compact

    dimensions.

    Digital controllers Primary and secondary controls are digitalized, enabling

    excellent monitoring and regulation characteristics.

    Thus, the number of component has been reduced by

    40% - for highly reliable, long life, trouble free DC

    • Software release 8. Model XR02CX, format 32 x 74 x 50 mm, is a digital thermostat with off cycle defrost designed for NOTE2: the set value is stored even when the procedure is exited by waiting the time-out to expire. • L2 message is displayed. INSTALLATION AND MOUNTING NOTE: Fast-on maximum current 16A Instrument XR02CX shall be mounted on vertical panel, in a 29x71 mm hole, and fixed using the special bracket supplied. Dixell controller DEFAULT SETTING VALUES The temperature range allowed for correct operation is 0÷60 °C.

    power systems.

    Heat management Front-to-back air flow with chassis-integrated heat sinks

    gives the module the most suitable working

    environment and no limitations in the scalability of the

    desired system solution.

    Unique connection

    A true plug-and-play connection system: time-to-install

    and cost-reducing solution.

    Global approvals Flatpack2 is CE marked, UL recognized and NEBS

    certified for world wide installation.

    Product Description

    The Flatpack2 is a battery charger and rectifier for

    stand-alone use or for working in parallel as part of a

    DC power system controlled and monitored by the

    Smartpack.

    Flatpack2 is optimized for a wide range of system sizes.

    Digital communication over CAN bus with Smartpack

    simplifies system design and enhances flexibility.

    Realization of Flatpack2 systems is possible by fitting 5

    rectifiers across a 23 shelf and 4 rectifiers across a 19

    shelf. How to protect a word file by password.

    Applications

    Wireless, fiber and fixed line communication

    Todays communications demand state of the art, cost

    efficient and compact DC power systems. Flatpack2

    delivers the industry leading power density of 22W/in3

    and superb reliability at lowest lifetime cost.

    Broadband and network access

    Increasing network speed demands flexible and

    expandable DC power solutions. Flatpack2 is your key

    building block for future needs.

    Flatpack2 Switch Mode Power Supply 48VDC

    109.00

    41.5

    0

    327.22

    (coming up)

    109 mm 327 mm

    41,5

    mm

  • Location Company Telephone Fax Europe Eltek Energy AS +47 32 20 32 00 +47 32 20 32 10 Americas Eltek Energy, LLC +1 815 459 9100 +1 815 459 9118 Asia/Pacific Eltek Energy Pte Ltd. +65 6 7732326 +65 6 7753602 China Eltek Energy Ltd. +852 28982689 +852 28983189 Middle East Eltek Middle East +971 4 887 1176 +971 4 887 1175

    www.eltekenergy.com I www.flatpack2.com

    Flatpack2 Additional Technical Specifications AC Input

    Voltage 85-300 VAC (Nominal 185 275 VAC)

    Frequency 45 to 66Hz

    Maximum Current

    12.5 Arms maximum at nominal input and full load

    Power Factor > 0.99 at 20% load or more

    Input Protection Varistors for transient protection Mains fuse in both lines Disconnect above 300 VAC

    DC Output Voltage 53.5 VDC (adj. range: 43.5-57.6 VDC)

    Output Power 2000 W at nominal input

    Maximum Current 41.7 Amps at 48 VDC and nominal input

    Current Sharing 3% from true average current between modules

    Static voltage regulation

    0.5% from 10% to 100% load

    Dynamic voltage regulation

    5.0% for 10-90% or 90-10% load variation, regulation time < 50ms

    Hold up time > 20ms; output voltage > 43.5 VDC at 1500W load

    Ripple and Noise < 100 mV peak to peak, 30 MHz bandwith < 0.96 mV rms psophometric

    Output Protection Overvoltage shutdown Blocking diode Short circuit proof High temperature protection

    Other Specifications Efficiency Typical 92%, min. 91% at 40-90% load

    Isolation 3.0 KVAC input and output 1.5 KVAC input earth 0.5 KVDC output earth

    Alarms: Warnings:

    Low mains shutdown High temperature shutdown Rectifier Failure Overvoltage shutdown on output Fan failure, one or two fans. Low voltage alarm at 43.5V CAN bus failure Low temperature shutdown Rectifier in power derate mode Remote battery current limit activated Input voltage out of range, flashing at overvoltage Loss of CAN communication with control unit, stand alone mode

    Visual indications

    Green LED: ON, no faults Red LED: rectifier failure Yellow LED : rectifier warning

    Operating temp

    -40 to +75C (-40 to +158F)

    Storage temp -40 to +85C (-40 to +185F)

    Cooling 2 fans (front to back airflow)

    Fan Speed Temperature and current regulated

    MTBF > 350, 000 hours Telcordia SR-332 Issue I, method III (a) (Tambient : 25C)

    Acoustic Noise < 55dBA at nominal input and full load (Tambient < 30C)

    Humidity Operating: 5% to 95% RH non-condensing Storage: 0% to 99% RH non-condensing

    Dimensions 109 x 41.5 x 327mm (wxhxd) (4.25 x 1.69 x 13)

    Weight 1.9 kg (4.19lbs)

    Applicable standards Electrical safety IEC 60950-1

    UL 60950-1 CSA 22.2

    EMC ETSI EN 300 386 V.1.3.2 (telecommunication network) EN 61000-6-1 (immunity, light industry) EN 61000-6-2 (immunity, industry) EN 61000-6-3 (emission, light industry) EN 61000-6-4 (emission, industry) Telcordia NEBS GR1089 CORE

    Harmonics EN 61000-3-2

    Environment ETSI EN 300 019-2 (-1, -2, -3) ETSI EN 300 132-2 Telcordia NEBS GR63 CORE Zone 4 RoHS compliant (pending)

    Specifications are subject to change without notice. ORDERING INFORMATION

    Part no. Description

    241115.100 Flatpack2 48/2000

    Document Rev. No.: 241115.100.DS3 v.02

Installation Manual

Advertisement

Related Manuals for Aquafilter FP2

Summary of Contents for Aquafilter FP2

  • Page 1: Installation Manual

    Installation Manual..
  • Page 2 ® ® Use only genuine Aqua Market and Aquafilter replacement parts, filter cartridges and membrane elements. In case of use of other manufacturers' parts, Aquafilter is not responsible for any damages caused in the course of product use. 2. Technical Specifications Inlet water temperature...........between + 2 C (+ 35 F) and + 45 C (113 F)
  • Page 3 FP2, FP3-2, FP3-K1, FP3-HJ-K1, FP3-3, FP3-4, FP3-5 the element is a part of the system: FP2, FP3-2, FP3-3, FP3-4, FP3-5 the element is a part of the system: FP3-K1, FP3-HJ-K1 the element is a part of the system: FP3-2..
  • Page 4 4. Connecting Flexible Tubing with Quick Connectors: JG (John Guest) and QC (Quick Connector) Disconnect Flexible Tubing: 1) Remove safety clip from the quick connector (if applicable) (Fig. 1). 2) Press on the flange of quick connector (Fig. 2). 3) Pull out flexible tubing (Fig. 3). Connect Flexible Tubing: 1) Push the flexible tubing 1.5 cm (0.6 in) deep into the quick connector (Fig.
  • Page 5 5. Preparing systems FP3-2, FP3-K1, FP3-HJ-K1, FP2, FP3-3, FP3-4, FP3-5 for installation Cartridge configuration for individual systems - refer to Table 1. Position the O-ring into the socket of filter head. Stretch Before placing the O-ring inside filter head, apply white o-ring properly and carefully arrange it in the socket cosmetic Vaseline to it.
  • Page 6 FP3-2 FP3-K1 FP3-3 FP3-HJ-K1 FP3-4 FP3-5 Housing 1 FCPS5-AQM FCPS20 FCPS5 FCPS5-AQM FCPS5 FCPS5-AQM FCPS5-AQM Housing 2 FCCBL-AQM FCCBL FCCST2 FCCST-AQM FCCST2 FCCST-AQM FCCST-AQM Housing 3 FCPS5 FCCBKDF FCCBL-AQM FCCBKDF FCCBL-AQM FCCBL-AQM In-line filter cartridge 1 TLCHF-2T TLCHF-FP TLCHF-FP In-line filter cartridge 2 AIFIR1000 Table 1.
  • Page 7 5.2 . Preparing FP3-4 system for installation: UF membrane installation Prior to system installation, first install a hollow fiber membrane: Remove plug-in from the inlet connector and UF membrane Use tubing to connect filtration system (start from elbow outlet. OUT) with UF membrane. WARNING! UF membrane is soaked with a special conserving solution.
  • Page 8 6. System Installation - Stage I WARNING! Manufacturer is not responsible for any damages that result from improper installation or use of system. System installation should be performed only in temperatures above 2°C (35.6°F). Shut off cold water supply valve. Unscrew flexible tubing from the shut-off valve (or the adapter).
  • Page 9 6.1. System Installation Option II - Wall Faucet Shut off water supply valve. Unscrew sink faucet from the wall. Screw chrome-plated adapter FT07 onto cold water pipe to Wind a few layers of Teflon Tape TAS0003 on shut-off valve allow easy SEWBV1414 valve installation and its easy adapter SEWBV 1414.
  • Page 10 (all the way) into the faucet extension [4] and tighten it (by hand!) with the metal nut [10]. System FP2, FP3-2, FP3-K1, FP3-3 6) Push other end of flexible tubing with (OUT) elbow of the system.
  • Page 11 8. Filtration Cartridges Description / Filtration Stage Longevity* Dimensions Cartridge Type PS20 Sediment, cold water cartridge for 10” housing. Designed for pre- filtration of tap and general-use water prior to the main filtration process. Cartridge stops sand, rust particles, sediments and impurities 9 7/8”..
  • Page 12 Cartridge replacement in the following systems: FP2, FP3-2, FP3-3, FP3-K1, FP3-HJ-K1, FP3-4, FP3-5 Close your water supply valve. Open faucet valve to release Unscrew filter housing sump from filter cap by hand or using pressure build-up in the system. wrench (FXWR1-BL). (Remember to use wrench perpendicularly to the filter housing).
  • Page 13 10. UF membrane replacement: FP3-4 Shut off water supply valve. Open filter faucet to release pressure from the system. Push in the flange and pull out flexible tubing. Remove UF membrane housing from mounting clips. Unscrew inlet and out let connectors from the UF Remove all layers of old Teflon tape and apply mutliply membrane.
  • Page 14 Push in membrane housing into mouting clips. Insert flexible tubing (all the way) into both ends of UF WARNING! While installing UF membrane, remember to membrane. keep the proper direction of water flow (indicated by an NOTE ! Check if inlet/outlet tubings are correctly and arrow on membrane sticker).
  • Page 15 Unscrew inlet and out let connectors from the membrane. Remove all layers of old Teflon tape and apply mutliply layers of new one. NOTE! Ensure that Telflon tape is winded in the opposite direction to the direction connector will be installed.
  • Page 16 10.2. Replacing UF membrane and filter cartridge AIFIR1000 in FP3-5 system Disconnecting UF membrane and filter cartridge AIFIR1000 Shut off water supply valve. Open filter faucet to release from the system. First, disconnect tubing from the inlet pressure build-up in the filter. connector attached to hollow fiber membrane.
  • Page 17 Unpack UF membrane and remove plug-ins. Screw-in connectors into new UF membrane housing. CAUTION! Don't backtrack during screwing in the connectors. Backtracking connectors may result in compromising the connection seal and water leaks. Unpack new filter cartridge AIFIR1000 and remove plug-ins Move mounting clips from old to the new filter cartridge from the inlet and outlet.
  • Page 18 Connecting filter cartridge AIFIR1000 and UF membrane. Connect filter cartridge AIFIR1000 and UF membrane by First, connect tubing coming out of AIFIR1000 inlet with UF placing UF membrane into mounting clips, which are already membrane outlet connector. CAUTION! During the installed on the system mounting bracket.
Comments are closed.